首頁(yè) > 標準下載>ASTM C1871-2018 通過(guò)使用熱電離質(zhì)譜計的雙同位素稀釋劑法測定鈾同位素組成的方法 Standard Test Method for Determination of Uranium Isotopic Composition by the Double Spike Method Using a Thermal Ionization Mass Spectrometer免費下載
ASTM C1871-2018 通過(guò)使用熱電離質(zhì)譜計的雙同位素稀釋劑法測定鈾同位素組成的方法 Standard Test Method for Determination of Uranium Isotopic Composition by the Double Spike Method Using a Thermal Ionization Mass Spectrometer ASTM C1871-2018 通過(guò)使用熱電離質(zhì)譜計的雙同位素稀釋劑法測定鈾同位素組成的方法 Standard Test Method for Determination of Uranium Isotopic Composition by the Double Spike Method Using a Thermal Ionization Mass Spectrometer

ASTM C1871-2018 通過(guò)使用熱電離質(zhì)譜計的雙同位素稀釋劑法測定鈾同位素組成的方法 Standard Test Method for Determination of Uranium Isotopic Composition by the Double Spike Method Using a Thermal Ionization Mass Spectrometer

  • 標準類(lèi)別:
  • 標準大?。?/li>
  • 標準編號:ASTM C1871-2018
  • 標準狀態(tài):現行
  • 更新時(shí)間:2023-08-18
  • 下載次數:次
標準簡(jiǎn)介

1.1 This test method describes the determination of the isotope amount ratios of uranium material as nitrate solutions by the double spike (DS) method using a thermal ionization mass spectrometer (TIMS) instrument. 1.2 The analytical performance in the determination of the 235U/238U major isotope amount ratio by the DS method is five to ten times better in terms of the internal and external reproducibility compared to the (“classical”) total evaporation (TE) method as described in Test Method C1672 and the “modified total evaporation” (MTE) as described in Test Method C1832. This is due to the use of an internal rather than external mass fractionation correction by using a double spike material with a known or certified 233U/236U isotope ratio, which is mixed with the sample prior to the measurement, either during the sample preparation or directly on the TIMS filament. 1.3 The DS method cannot be applied for the determination of the 236U/238U minor isotope amount ratio, and is also not recommended for the determination of the 234U/238U minor isotope amount ratio. 1.4 In case the uranium amount concentration of the double spike is known or certified, the uranium amount concentration of the sample can be determined using the isotope dilution mass spectrometry (IDMS) method as described in Test Method C1672, by blending the sample gravimetrically with the double spike and performing a DS measurement. 1.5 An external mass fractionation correction by measurements of a certified reference material loaded on different filaments and measured in the same measurement sequence, as recommended for TE and required for MTE measurements, is not necessary for the DS method. However, for quality control (QC) purposes it is recommended to perform DS measurements of low enriched or natural uranium isotopic reference materials on a regular basis. 1.6 The DS method can only be applied to uranium samples with rel

標準截圖
下一條:返回列表
版權:如無(wú)特殊注明,文章轉載自網(wǎng)絡(luò ),侵權請聯(lián)系cnmhg168#163.com刪除!文件均為網(wǎng)友上傳,僅供研究和學(xué)習使用,務(wù)必24小時(shí)內刪除。
欧美AAAAAA级午夜福利_国产福利写真片视频在线_91香蕉国产观看免费人人_莉莉精品国产免费手机影院