首頁(yè) > 標準下載>ASTM F855-2017 斷電狀態(tài)的電源線(xiàn)和設備用臨時(shí)保護性接地規格 Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment免費下載
ASTM F855-2017 斷電狀態(tài)的電源線(xiàn)和設備用臨時(shí)保護性接地規格 Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment ASTM F855-2017 斷電狀態(tài)的電源線(xiàn)和設備用臨時(shí)保護性接地規格 Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment

ASTM F855-2017 斷電狀態(tài)的電源線(xiàn)和設備用臨時(shí)保護性接地規格 Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment

  • 標準類(lèi)別:
  • 標準大?。?/li>
  • 標準編號:ASTM F855-2017
  • 標準狀態(tài):現行
  • 更新時(shí)間:2023-07-01
  • 下載次數:次
標準簡(jiǎn)介

1.1 These specifications cover the equipment making up the temporary grounding system used on de-energized electric power lines, electric supply stations, and equipment. 1.2 It is common practice for the users of protective grounding equipment to prepare complete instructions and regulations to govern in detail the correct use and maintenance of such equipment. 1.3 The uses and maintenance of this equipment are beyond the scope of these specifications. 1.4 These specifications for a system of protective grounding utilizing copper cables are covered in four parts, as follows:           Sections Clamps for Temporary Protective Grounds   4 – 16 Ferrules for Temporary Protective Grounds   17 – 30 Cables for Temporary Protective Grounds   31 – 39 Protective Grounds (Complete Assembly With Clamps, Ferrules,   and Cable)   40 – 52 1.5 Each of the four parts is an entity of itself, but is listed as a part of the system for completeness and clarification. 1.6 Currents presented in Table 1 are based upon cable melting times, as determined from equations by I. M. Onderdonk and are to used in situations involving an asymmetry value less than 20 % (X/R ≤ 1.8). See Appendix X1. (A) Withstand and ultimate short circuit properties are based on performance with surges not exceeding 20 % asymmetry factor (see 9.1 and 12.3.4.2).(B) Yield shall mean no permanent deformation such that the clamp cannot be reused throughout its entire range of application.(C) Ultimate rating represents a symmetrical current which the assembly or individual components shall carry for the specified time.(D) Ultimate values are based upon application of Onderdonk's equation to 98 % of nominal circular mil area allowed by Specifications B172 and B173. Note 1: TPG testing is done on com

標準截圖
下一條:返回列表
版權:如無(wú)特殊注明,文章轉載自網(wǎng)絡(luò ),侵權請聯(lián)系cnmhg168#163.com刪除!文件均為網(wǎng)友上傳,僅供研究和學(xué)習使用,務(wù)必24小時(shí)內刪除。
欧美AAAAAA级午夜福利_国产福利写真片视频在线_91香蕉国产观看免费人人_莉莉精品国产免费手机影院