ASTM F3291-2017 薄膜測力傳感器力與電阻測量方法 Standard Test Method for Measuring the Force-Resistance of a Membrane Force Sensor

  • 標準類(lèi)別:
  • 標準大?。?/li>
  • 標準編號:ASTM F3291-2017
  • 標準狀態(tài):現行
  • 更新時(shí)間:2023-05-18
  • 下載次數:次
標準簡(jiǎn)介

1.1 This test method covers the force versus resistance measurement of a membrane force sensor (MFS) where the electrical resistance decreases as the force on the sensor is increased. 1.2 An MFS may or may not be electrically open in its static state. This depends on the attributes required for the application. If the MFS has a measureable resistance in static state, it was most likely designed to be used as a variable resistor, not as a normally open switch. A high but measurable resistance, in static state, may still be considered an open switch if the resistance is above the closed resistance threshold recognized by the interface electronics. 1.3 Special printed conductive polymer inks or characteristics, or both, of the sensor design are used in MFS to achieve variable resistance when compressed. As force is applied to the MFS the resistance continues to decrease, but not linearly, until a point where additional force does not change the resistance appreciably. Ideally, when force is removed from the MFS the resistance will return to, or close to, its original value. 1.4 Materials other than conductive polymers can be used in an MFS and also exhibit reduced resistance with increasing force. 1.5 This test method should not be confused with Test Method F2592 for measuring the force-displacement characteristics of a membrane switch (MS) that is designed for momentary closure. Although the resistance of a MS does change during contact closure the change from high resistance to contact resistance is very sudden and additional force does not have a significant effect on the resistance; that is, an MS is not designed to be used as a variable resistor. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organizatio

標準截圖
版權:如無(wú)特殊注明,文章轉載自網(wǎng)絡(luò ),侵權請聯(lián)系cnmhg168#163.com刪除!文件均為網(wǎng)友上傳,僅供研究和學(xué)習使用,務(wù)必24小時(shí)內刪除。
欧美AAAAAA级午夜福利_国产福利写真片视频在线_91香蕉国产观看免费人人_莉莉精品国产免费手机影院